The capacities of the EX20 / EX50 / EX150 / EX500 regenerators range from 20 to 500 litres, for a recycling rate of 100 to 2500 litres per day.
Standard regenerators are equipped with:
• A tilting mechanism
• A residue outlet at the back
• Temperature and level probes
• A control box
1. The solvent used is poured into the stainless steel tank of the regenerator.
2. It is then heated by the Aluminium heating plate.
3. When the solvent reaches its boiling point, it goes into the vapour phase, which is naturally collected in the condenser.
4. The pure solvent vapour is cooled via a water condenser system allowing optimal heat exchange.
5. A 100% pure solvent is harvested and ready to use.
6. The residue, also called a contaminant, is recovered in the regenerator tank, either manually or automatically.
Our unique patented bottom heating system has the following advantages:
• Almost no maintenance
• Very high efficiency
• Quick and easy cleaning
• Significant energy savings
The vacuum system allows the operating temperature to be reduced.